Another interesting option, although it won’t work for most people, is the Emporia “Vue Utility Connect wireless energy monitor. 00 Shop EV Chargers + Installation!All My Favorite Tools - I wanted to crank up my ability to monitor the energy consumption in my home and deci. Safety information Personal protective gear should be worn when installing the Emporia Vue. Making sure your breaker for the solar is off and you are within bluetooth range of the Gen 2 Vue. Thanx to a viewer's feedback. This is best done by a professional or competent home owner. Plug in the unmodified end of the cable we modified above into the IO0 pin of the Emporia Vue 2. py --chip esp32 erase_flash. 99 Emporia Gen 2 Vue energy monitor — including only the mainline sensors — Emporia sells. Your phone will connect via Bluetooth to the system and then you’ll connect to a nearby Wi-Fi router. EN | ES. If there were more of them I might try something more structured. Can also monitor Solar metering. This is in the newest addition. consuming a lot of space inside the cracker box. Download VUE for the Mac OS. Articles to help understand how the Gen 2 works as well as troubleshooting. For its part, Eyedro requires peripheral equipment and cannot resolve individual-circuit data. 2) Subpanel mains clamps: Arrow points from feeder->subpanel. WiFi Signal Strength Meter can quickly check your WiFi strength to find the best location. You'll know exactly how much energy you're using in real time and historically by the minute, hour, day, week, month, and year. The Vue wants those two wires to be on opposite legs/phases. 2 but only connected the main CT (s) on PNL. I did the Vue 2 install myself and my main panel is recessed. This helps you cut down or just give you more insight. You can see at the bottom that I had the time scale set to seconds. Comes with sixteen (16) 50A sensors to monitor individual circuits - Add up to eight more. Except for Tesla’s home charger, I’ve tested all the leading contenders for best home EV charger in the smart category – ChargePoint, Electrify America, Grizzle-E Smart, and Emporia Energy. 1″ conduit is just big enough for the ell-shaped CT plugs to wiggle through even when you already have seven. Vue sensors provide 1-second data and are accurate from ±2%. lambda: 'return max(x, 0. Phone: 844-EMPORIA (367-6742) Email: support@emporiaenergy. The Tesla app is great to see the balance of the grid, solar, battery, and home consumption, but it doesn't provide much insight to what is actually happening in the home. I got a 6″x6″x4″ PVC junction box and used two short 1″ conduit pieces to connect it to the load center. 99. The Gen 2 Vue from Emporia is a low-cost way to understand and manage your tenants energy use. However, if you don’t have a solar installation at the moment, you can opt for the non-solar Sense monitor. Brand: EMPORIA | Category: Monitor | Size: 1. Step 1 esptool. Emporia Smart Plugs are now in the UK and EU. The former costs more than the latter. Online instruction manual. Installation Compatibility Note. next page →. v0. Note: This project is not associated with or endorsed by Emporia Energy. It supports either single-phase up to 240VAC line-neutral; single, split-phase 120/240VAC; and three-phase up to 415Y/240VAC (no Delta). Emporia Smart Plugs: The Perfect Encore. You don’t want to do that for unbalanced loads (those devices which have a neutral connection) or subpanels. Get the App. . Check out. my credentials are correct. Do You have Metal Bus Bar Mains in Your Panel? Our Flexible Current Sensor solution is now available on. No local mode is a severe limitation . 6" x 1. 1″ conduit is just big enough for the ell-shaped CT plugs to wiggle through even when you already have seven. It was easy to install and configure and it integrated into HA without issue. 1 second data is retained 3 hours, 1 minute data is retained 7 days, 1 hour data is retained. REAL-TIME ENERGY DATA: REQUIRES 2. The Vue installs in the. Emporia helps households make wise choices with hardware prices starting at a low $11. Great for Energy savings, real time utility bills, solar installations and net metering. REAL-TIME ENERGY DATA: REQUIRES 2. That happens automatically with regular single breakers (like for your high power loads, like the range and water heater) r/homeautomation. The syntax is a subset of the crontab syntax. Gen 2 Vue. Install Emporia Vue Energy Monitor for my home (How the Gen 2 Vue Energy Monitor Works). js and the concept of build tools, you can also try a complete build setup right within your browser on StackBlitz. Emporia has developed the next generation of the Vue Energy Monitor. It comes with a 24’ cable with an SAE. Features – Power the Vue directly from a 15A or 20A breaker – Granular 1-second data interval – Operates regardless of your utility – Interact with your Emporia Vue through your mobile device or laptop – Real-time monitoring of your energy usage and production with helpful units and measurements This guide assumes that you have already installed the Emporia Vue in your circuit panel using its Installation Guide. Emporia Vue. If you are using the [magico13/ha-emporia-vue] integration in Home Assistant, the data will already be appearing in the InfluxDb database. 1) Download and install “BlueStacks” from BlueStacks. You can also add them to the devices to see a comparison. A has 30 branch circuits, in which I want to monitor all 30. . Creates a sensor for each device channel showing average usage over each minute. Disconnect the EN and IO0 cables from ground. Select Emporia Vue Circuit Daily Energy Entities or Total Daily Energy. Vue. Note possible variation between Windows and Linux described above to have success with the install. The Vue platform from Emporia Energy gives occupants the insight necessary to save real money. Emporia Vue Home Energy Monitor review Install a private detective for energy use The Gadgeteer, Features:, 100% brand new and high Plug and play, simply plug the meter into the wall and connect your Can monitor the standby orMighty Gadget's review of Emporia's UK Smart Plugs found them to be ". 08/3. A Python Library for reading data from the Emporia Vue energy monitoring system. THE FIRST 200 PEOPLE TO PURCHASE AN ENERGY MONITOR GET A $30 BILL CREDIT FROM CFU! By purchasing this product from Emporia, you agree to allow Emporia to share your name and address with Cedar Falls Utilities so they can issue bill credit; if eligible. After downloading, double click the VUE. I like to add each circuit to the consumption. Maybe this will help someone else get it right the first time. 99 $23 99 $23. 3. REAL-TIME ENERGY DATA: REQUIRES 2. Monitor the whole house AND individual circuits with the Emporia VUE. When used as a plug-in charger, the unit is limited to 40-amps, which will deliver up to 9. I would recommend this device. The most important thing to remember is, TURN OFF THE MAIN BREAKER TO THE PANEL YOU ARE INSTALLING IT IN. Project description. 844-EMPORIA (367-6742) Complies with part 15 of the FCC Rules I. 0 and finally implement an energy monitoring solution so we reached out to the awesome folks at Emporia. 5. 25*0. yaml is saved, we can add it to the main Home Assistant config like so. Emporia smart home energy monitorThe best home energy monitors of 2023 Emporia energy vue monitor 50a real turning knowledge power intoGen 2 emporia vue smart home energy monitor with 16 50a circuit level. Emporia Vue. If anyone would like to buy and try , there is 10% off from official website : ten%offk. Vue-CLI chuẩn bị sẵn các cài đặt phong phú cho một quy trình front-end hiện đại. GitHub Gist: instantly share code, notes, and snippets. . Just like our existing electric and natural gas meters, smart meters record your energy usage. I used an 8x6x4 box with a hinged lid and lots of knockouts to house the monitor. Linux / Generic JAR-only version (no installer included)Once you feel like you have something you want to upload to your ESP board, simply plug in the device via USB and type the following command (replacing livingroom. The separate box has a hinged door so it’s easy to open and switch the CTs. The following command dumps the entire flash: $ esptool. Talk to a real person at Emporia! 8AM – 5PM US Mountain Time: Monday – Friday. Share free summaries, lecture notes, exam prep and more!!Detailed energy monitoring with Emporia Gen2 Vue. Plugs into your Emporia Vue; Easy installation; 3-PHASE GEN 1 VUES ARE NOT SOLAR CAPABLE; Must be used with the Emporia Vue. Instead of trying to figure out what runs based on listening to the two mains only, Emporia provides you with up to sixteen extra sensors, you can add directly to the circuits of your electricity panel. About 18 months ago I purchased two Emporia Gen2 Vue devices and outfitted 16 circuits in each of my two electrical panels. . 7. Works with all electric cars. 7" x 1. It reports. The most engaged homeowners and renters may achieve as much as 50% in avoided costs. 3. Select Integrations. If you believe any of the Emporia Vue components may have been damaged, do not attempt to use them. pip install pyemvue Copy PIP instructions. However, as a reward for installation, the Vue provides highly granular data and the ability to monitor individual. The Rundown. Your phone will connect via Bluetooth to the system and then you’ll connect to a nearby Wi-Fi router. In this configuration, your balance on Vue2 #1 will equal the sum of the circuits on Vue #2, and all the math will still work. That means the conduit must be pullable - you must put appropriate sweeps or "conduit bodies" (corners or Tees with access covers) where they'll be needed. when i get to the logger portion of installing, nothing shows in the terminal, it just sits as. Do not install the Emporia Vue in environments with explosive gas or vapors; nor in damp or wet environments; nor in direct sunlight; nor where temperatures are consistently below -40° F (-40° C) or above 122° F (50° C). Emporia News. I’ve contacted Emporia and they suggested the I should connect the red and blue to the neutral bar that the black power wire is associated with and the white neutral wire should be in. The Vue is UL and CE Listed for your safety. Page 1 Emporia Vue Utility Connect User Guide Installation Guide Device Release Notes. 77 MB Table of Contents. The kasa and wemo integration is a huge help for me. Works with all electric cars. Then download the Emporia app in Bluestacks. The Vue is UL and CE Listed for your safety. You can also add Emporia Smart Plugs to monitor the plugged in appliances and lights you care about. Negatives: The wiring for 18 sensors in a relatively small. REAL-TIME ENERGY DATA: REQUIRES 2. If you believe any of the Emporia Vue components. If you believe any of the Emporia Vue components may have been damaged, do not attempt to use them. Setup a Gen 2 for. The Gen 2 Vue from Emporia is a low-cost way to understand and manage your tenants energy use. Set alerts for times when usage is approaching monthly peak energy use, when lights or ovens are left on, when things like sump pumps don't turn off, or when an A/C uses more energy than it should. Energy Monitor Connections. or. or . Solar Monitoring. WiFi Connectivity, Not Connecting. The Emporia Vue smart home energy monitor is a cost-effective way to keep track of energy activity in your house. 3. Does my Gen 2 need a multiplier on "mains" for a 240V system? CT Sensors - Proper alignment, placement. Took the measured usage "should" (from another meter or maths) (4. Installing an Emportia Vue 2 on my electrical panel - complete setup, including connecting app. The Vue is UL and CE Listed for your safety. All of my branch circuits, including 2x240v 30a’s with 2x multiplier are reading as. Done! Installing an Emportia Vue 2 on my electrical panel - complete setup, including connecting app. EMPORIA Vue Installation Manual (26 pages) Smart home energy monitor. 022, so 1. . 2. Additionally, you can add 50A sensor. 5 out of 5 stars 3,793 ratings. I have a 200A load center, and a 30A backup generator. Black harness wire and an extra wire with a. This guide assumes that you have already installed the Emporia Vue in your circuit panel using its Installation Guide. 0. 2; 2; 2 months, 1 week ago. The Emporia Electric Vehicle Charging Station is a Level 2 electric vehicle charger that charges any EV up to 40 amps with NEMA 14-50P or up to 48 amps with hardwired installation. Lower your electric bills! With the Emporia Vue Real Time 24/7 Electricity Monitor for the home. @mattclar, are you sure you didn’t change the uart section of your yaml file? It should look like: # This uart connects to the MGM111 uart: id: emporia_uart rx_pin: GPIO21 tx_pin: GPIO22 baud_rate: 115200 There is a very small chance that emporia has a new version of the board and moved the serial port around, I’d confirm that you board. Emporia Smart Plug | Set of 4 Energy Monitoring Outlets $34 99 $34. Is the Emporia Vue 2 easy to install by a layman at all? I am comfortable doing standard electrical stuff like swapping switches, receptacles, and light sockets. Creates a sensor for each device channel showing average usage over each minute. All (2581) Featured. 4) Open the newly installed Emporia Energy app. All of my branch circuits, including 2x240v 30a’s with 2x multiplier are reading as. PyEmVue. Ensure. Was interested in Smappee, Sense, Emporia Vue Gen1… and finally got my Vue Gen2 last week. 5mm. Power the Vue directly from a 15A or 20A breaker. Another interesting option, although it won’t work for most people, is the Emporia “Vue Utility Connect wireless energy monitor. Its watertight black or white NEMA Type 4 enclosure is made to withstand. Do you want to monitor your home energy usage and save money on your bills? Learn how to install the Emporia Vue, a smart energy management system that connects to your circuit breaker panel and provides real-time data and insights. Would. Step 2: Install vuegraph on your compute device. 75; 405; 23 hours, 11 minutes ago. I really like it, it's great to have power data. Technical specifications for Emporia Gen 2 Vue, Emporia EV Charger, Emporia V2X Charger, Alpha-ESS Home Battery Systems, Emporia Current Sensors, Vue Utility Connect, and Emporia Smart Plugs. I would guess So as long as the emporia cloud is up you can copy data to HA. Anther home energy monitor: Sense – EnergyAlso, since it’s about 36″ high, the cables are a bit too short, they would need to be about 6″ longer. The sense app is more intuitive. Some installation notes: I used off-the-shelf mono audio extension cables for the far sensors. It reports. 0 for home energy monitoring of 120/240V loads. Affiliate link: Get 5% off (plus I get 5%) by using this link: monitors are a great way to figure out what in your house is. Bring this data into the Home Assistant Energy Portal and build beautiful graphs in Gra. If you believe any of the Emporia Vue components may have been damaged, do not attempt to use them. Gen 2 Emporia Vue Smart Home Energy Monitor – Editor's Choice. Emporia Vue: Gen 2 with 16 Sensors & Pair of Flexible Current Sensors Regular price $214 99 $214. Vue does not support IE8 and below, because it uses ECMAScript 5 features that are un-shimmable in IE8. Before You Get Started. Reads data from the Emporia Vue energy monitor. 5mm. Get an Emporia PowerStation!Easy Installation Guide for Emporia Vue: Monitor Solar and Energy Usage • Emporia Vue Installation Guide • Learn how to easily install the Emporia Vue for so. The Emporia Vue Energy Monitor installs in an electrical panels. Then you’ll connect the Vue to your nearby Wi-Fi network. Unofficial library for interacting with the Emporia Vue energy monitor. Bring this data into the Home Assistant Energy Portal and build beautiful graphs in Gra. Then add one webpage card and paste the link from above. I have a Hybrid Solar system with a Battery, and therefore I have a Sub panel with the house critical. Anther home energy monitor: Sense – Energy* Professional installation recommended. Details about nesting and using multiple devices together can be found here. Emporia’s system, however, costs much less than Sense’s: The Emporia Vue base unit is just $50, plus another $60 if you choose to add the eight circuit-specific sensors (you can buy the two. Stars. Emporia Vue: The Cost-effective Electric Sub-meter for Rental Units. The Emporia App also suggests valuable savings. 5mm. Added in: 3D Printing (3) Alarm (48) Automation (27) Binary Sensor (199) Button (54) Calendar (11) Camera (52) Car (15) Climate (118) Cover (100) Date (29) Date/Time (1) Device Automation (1) Device Tracker (3) DIY (22) Doorbell (8. I decided to go with the Vue Utility Connect ($39) which communicates with supported electric meters over ZigBee. 5mm for. Start Your Journey in Three Easy Steps Step 1: Try Emporia's Software Download Emporia's home energy app on either the App Store or Google Play. Data is pulled from the Emporia API using the PyEmVue python module, also written by me. It comes with a 24’ cable with an SAE J1772 connector so it works with all electric cars. Emporia News. Enable the panel mode to make your Grafana panel use the full space and give it a title. I just finished reinstalling my Vue Gen2 with 16 sensors. If you believe any of the Emporia Vue components may have been damaged, do not attempt to use them. Unboxing, installing and configuring the Emporia app to monitor power usage. The Emporia Vue Utility Connect has passed all relevant tests in conjunction with the Zigbee Alliance Smart Energy Certification Program. If you believe any of the Emporia Vue components may have been damaged, do not attempt to use them. Compared to similar energy monitoring devices, the Emporia Energy Vue is a great value. The Emporia Energy Vue is a terrific energy monitor device. Learn how to tap into your savings by reading the posts. We are then natively exposing metrics in prometheus format from HomeAssistant and scraping those. Install 50A CTs on every circuit the tenant is. Started by: eranr. Make sure you have your Wi-Fi name and password. Metrics are then natively exposed in Prometheus format from HomeAssistant, and the result is this glorious dashboard. Ive got esphome to install through the terminal on my pc. Level 2 charging is completed with a 240V circuit, similar to what you use to power an electric oven or dryer. - 0. Install Vue 2 into “Do not break seal no fuses inside” compartment. I have a multi-meter and non-contact voltage detector for checking that a circuit is powered off. 6. A dashboard that shows your home energy usage. Solar Monitoring. Data is pulled from the Emporia API using the PyEmVue python module, also written by me. Even without thinking about the savings, the ability to run monitors on 8 individual circuits, and work with some inexpensive smart monitoring plugs, made this Emporia the right one for me. Professional installation recommended Granular 1-second data interval Operates regardless of your utility Add up to sixteen 50A sensors to monitor individual circuits. 99 depending on how many sensors you need and whether you choose the bundle option that includes the Sensi smart thermostat. This powerful automation can be used to run automations at specific intervals at specific times of day. . Schedule charging, track energy use, automate charge reduction for Peak Demand and Time-of-Use and Solar only Charging in the Emporia app. I am new to HA and I would like to install an integration with the Emporia VUE energy monitor. In contrast, the Emporia Gen 2 Vue offers continuous 1-second data; has the ability to monitor up to 16 individual circuits/appliances; and can integrate, automate, and control smart home devices to ensure you conserve and consume energy in a way that minimizes your energy bill. If you’re talking full on forced air, that may be a different story. Integrations. Welcome back to KwhOnly-EV. The author was using an Emporia energy monitor which seemed to have fairly positive reviews and was simple to install. Emporia Vue. However, it seems to be stuck in a boot loop, even after trying to flash it with ESPHome on another system. 2 Documentation. The Emporia PowerStation is a powerful, flexible, and full-featured energy platform that is capable of supporting multiple configurations and sizes of 10, 15, and 20 kWh. It comes with a 24’ cable with an SAE J1772 connector so it works with all electric cars. Do not install the Emporia Vue in environments with explosive gas or vapors; nor in damp or wet environments; nor in direct sunlight; nor where temperatures are consistently below -40° F (-40° C) or above 122° F (50° C). It also assumes that you have downloaded the Emporia app from the Apple App Store or Google Play and created an account in the app. This Emporia is highly regarded within the community, but it does involve disassembling and flashing the device with a custom. 1 second data is retained 3 hours, 1 minute data is retained 7 days, 1 hour data is retained indefinitely. It also assumes that you have downloaded the Emporia app from the Apple App Store or Google Play and created an account in the app. 5mm. The WiFi Signal Meter app is a simple tool that allows you to view your current WiFi signal strength. For the ones supported by HACS : simply click ‘install’ in HACS. The Emporia setup process went without a hitch, and the app is well-designed. I fixed the audio music in the background. Out of curiosity, does any one know of any alternative firmware projects for emporia view devices? i know the vue 2 has an esp32 at the heart of it. The following command dumps the entire flash: $ esptool. I did buy the knock-out punch set at Harbor Freight because it was $25 instead of $180. You can see at the bottom that I had the time scale set to seconds. Share installation photos. bin. . 3) Circuits clamps for loads: Arrow points from breaker->circuit wiring. Recently, I noticed it was offline, and it will not re-connect. The app is constantly updating the WiFi signal. Vue sensors provide 1-second data and are accurate from ±2%. They were excited to sponsor our energy project and provided us with six Emporia Vue Energy Monitors (the three phase flavor). Do not use the Emporia Vue in any manner other than specified in this installation guide. Installation Compatibility Note. Vue follows Semantic Versioning in all its official projects for documented features and behavior. At the top, it shows the total power use. Emporia Vue: Gen 2 Whole Home Energy Monitor Emporia If you're looking for an all-encompassing option for your home, you can snag the Emporia Vue: Gen 2 Whole Home Energy Monitor . Author. js cung cấp một CLI giúp nhanh chóng khởi tạo nền tảng (scaffolding) cho các ứng dụng một trang. Ensure. two vertically adjacent (stacked) 15A single. At this point, there’s a complete open source firmware based on ESPHome available for the Emporia Vue 2. next page →. Disclaimer . 29 or we're off by a factor of 1. . The Vue monitors the total energy use and solar net metering of your home through a simple iOS or Android app. The Emporia Vue energy monitoring kit allows homeowners to monitor their electrical usage. Do You have Metal Bus Bar Mains in Your Panel? Our Flexible Current Sensor solution is now available on. 6" x 1. Check Price. Emporia Installation Guides Emporia Installation Guides are built into the Emporia App! But you can also download Emporia Installation Manuals in PDF format to guide you through installing Emporia products. It supports either single-phase up to 240VAC line-neutral; single, split-phase 120/240VAC; and three-phase up to 415Y/240VAC (no Delta). This innovative solution adheres to the National Electric Code (NFPA 70) while dynamically adjusting the charger's load. Sense Flex. 75; 405; 23 hours, 11 minutes ago. 25"x 2. The regular Emporia Vue is nicer for 220V device monitoring since most 220V devices have their own circuit so it's obvious on the emporia which clamp is for which device. 5. py --port /dev/ttyUSB0 read_flash 0 0x400000 flash_contents. influxdb: !include influxdb. Once influxdb. 1 PNL. 200A sensor dimensions: 2. 6" (65mm x 44mm x 41mm) Window diameter: 1" (26mm) Cable length: 39" (1m) Connector plug: 3. 🛠️ Standard Tooling for Vue. They allow you to reuse # this configuration in each sensor, while only defining it once. See all 14 articles. 1 second data is retained 3 hours, 1 minute data is retained 7 days, 1 hour. 99. Emporia Vue 2 Installation. Emporia Smart Plug Review, Emporia Vue energy monitor review: Understand your home's energy consumption without breaking the bank TechHive, Emporia Vue Home Energy Monitor review Install a private detective for energy use The Gadgeteer. yaml. The Emporia App has valuable alerts that protect families and homes. Install was rather painless. It supports either single-phase up to 240VAC line-neutral; single, split-phase 120/240VAC; and three-phase up to 415Y/240VAC (no Delta). It does require shutting OFF your main breaker, this removes. My house is equipped with a 200A emergency service disconnect outside, the invoice from when it was installed reads "Install new 200A service disconnect outside of the house for emergency service disconnect. Emporia Vue: Gen 2 with 16 Sensors. The Vue is considered a non-invasive load monitor (NILM) and as a non-permanent fixture, it is acceptable to install in an electrical panel. Home assistant will stack the entities in the bar chart so you can get a visual of which circuit uses the most energy. Unboxing, installing and configuring the Emporia app to monitor power usage. Pre-Installation. The Vue Energy Monitor is connected directly to your electric meter and monitors its readings 24/7. Product link: an Emporia Vue 2 home electricity usage monitor. Click the button to indicate that you have installed your Emporia Vue and you’re ready to proceed. If you believe any of the Emporia Vue components may have been damaged, do not attempt to use them. Mac OS. 5mm for the 200A sensors and 2. For standard installation scenarios - this means that the 200A CT's will have the "K" pointing towards the grid/meter and the "L" in towards the. 5mm. ” If you happen to be in one of the relatively few markets using the appropriate Zigbee-connected smart meter, that cheap little device can tell you your total power draw by simply asking your existing smart. Vue sensors provide 1-second data and are accurate from ±2%. The "L" side should point towards appliance/consumption load and "K" represents power source. Installs indoors or out. Emporia Vue Smart Home Energy Monitor at a Glance. The Vue system is designed for field installation in a switch enclosure as per 312. Some installation notes: I used off-the-shelf mono audio extension cables for the far sensors. Includes expansion module for monitoring of. xyz. . In this video, Chris installs the Emporia Vue energy monitor in his electric panel. 99, we have worked hard to make our platform available to all! Price Product Whom it's for Installation Requirements What it is. Emporia Vue. The Emporia Smart Home Energy Management System helps reduce overall energy consumption by identifying and managing wasted energy and providing control over how energy is used throughout the day. If you believe any of the Emporia Vue components may have been damaged, do not attempt to use them. I like to add each circuit to the consumption. Great for Energy savings, real time utility bills, solar installations and net metering. Gen 2 Vue Solar Supplement. Jul 6, 2021. Feb 20, 2023. If you’re interested in solar, knowing your. For many, cost savings provide the strongest motivation for gaining a home with a Vue. Do not install the Emporia Vue in environments with explosive gas or vapors; nor in damp or wet environments; nor in direct sunlight; nor where temperatures are consistently below -40° F (-40° C) or above 122° F (50° C). Vue sensors provide 1-second data and are accurate from ±2%. 1. Download the esphome-emporia-vue-utility file from github. Emporia Vue: Gen 2 with 8 Sensors and Pair of Flexible Current Sensors Regular price $174 99 $174. 333VDC CT, can I use a third-party CT. 5mm plugs to connect to the main ports of a Gen 2 Vue. ESPHome Emporia Vue Utility Connect Unofficial Firmware . Edit configmcsMQTT. I compared the Vue 2 to the open source project IoTaWatt and the extra simple setup device GreenEye. Turn off the Main Breaker and Remove the Cover. Emporia Vue: Gen 2 with 8 Sensors and Pair of Flexible Current Sensors Regular price $174 99 $174. About 12h of work for the 11 Vue 2s and all the CTs inside the panels. I would wire the 4 power supply ac wires to a 120/240V plug outside the unit. Firstly, let's spin up a separate Docker container for it. 022 = 0. Granular 1-second data interval. Hello, I am new here and am wanting to purchase the Emporia Vue kit with the 8 sensors. Emporia Vue. WebflowEmporia offers an installation guide online and on the Emporia App for its energy monitor options. Open a console window and test that esptool.